Hiretech offers diesel driven Safe Area and ATEX Zone 2 certified high pressure positive displacement triplex pumps suitable for flows and pressures ranging from 50 lpm – 1500 lpm and pressures up to 1000 bar.

Pumps are packaged into standard 10 x 8, 12 x 8 and 20 x 8, DNV 2.7-1 certified containers for easy transportation and shipping. Plunger sizes range from 26 mm to 5”.

Suction and discharge hoses, iron, feed pumps, umbilical reels and accessories can also be supplied.

Typical applications for our pumps include high pressure water jetting, pressure testing, well servicing, decommissioning and chemical pumping.

Safe Area Volvo TAD1642VE / Hammelmann HDP382 HTP39

Specification

Engine TypeVolvo TAD 1642 VE  
Pump TypeHammelmann HDP382  
Length x Width x Height4877 x 2438 x 2830 mm  
Max Flow204 lpm  
Max Pressure1000 bar  
Maximum Gross Certified Weight15500 kg  
CertificationDNV2.7-1  

View Video File (3.0 MB)

Zone 2 Diesel Driven Fluid Pump Volvo TAMD

Zone 2 Volvo TAMD74A / HD500 HTP01

Specification

Engine TypeZone 2 Volvo TAMD 74A  
Pump TypeHD500, 3 ⅜” or 4 ½"  
Length x Width x Height6100 x 2430 x 2860 mm  
Max Flow1,548 lpm  
Max Pressure1034 bar  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  
Zone 2 Diesel Driven Fluid Pump HTP122

Zone 2 Caterpillar 3406 / SS600 Triplex Split Unit HTP122

Specification

Engine TypeZone 2 Caterpillar 3406  
Pump TypeHD600, 3 ⅜” or 4 ½"  
Length x Width x Height7200 x 2450 x 3315 mm (combined)  
Max Flow1,548 lpm  
Max Pressure1034 bar  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  
    

Zone 2 Detroit 16V92T / SPM2250 Triplex Split Unit HTP67, 68, 69

Specification

Engine TypeZone 2 Detroit 16V92TA  
Pump TypeSPM TWS2250 – 5”  
 Engine ContainerPump Container 
Length5480 mm3569mm 
Width2610 mm2420 mm 
Height2851 mm2730 mm 
Tare & Gross19,500 kg11,300 kg 
Actual Lift Weight16,500 kg11,300 kg 
Max Flow2552 lpm  
Max Pressure790 bar  

View Video File (4.2 MB)

Zone 2 High Horsepower Diesel Driven Fluid Pump Catepillar

Zone 2 Caterpillar 3412 / SPM TWS900 Split Unit HTP70, 71

Specification

Engine TypeZone 2 Caterpillar 3412  
Pump TypeSPM TWS900 – 4” or 4 ½”  
 Engine ContainerPump Container 
Length6095 mm3045 mm 
Width2590 mm2590 mm 
Height2910 mm2910 mm 
Tare & Gross Weight20,500 kg12,000 kg 
Actual Lift Weight20,500 kg12,000 kg 
Max Flow2067 lpm  
Max Pressure694 bar  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  
Zone 2 Diesel Driven Triplex Pump Set Ford

Zone 2 Ford 2726T / Aqua AHF215 Triplex HTP11

Specification

Engine TypeFord 2726T  
Pump TypeAqua AHF 215, 28mm, 35mm, 45mm, 55mm  
Length x Width x Height2993 x 2438 x 2830 mm  
Max Flow275 lpm  
Max Pressure1000 bar  
Gross Weight12800 kg  
CertificationDNV 2.7-1, ATEX  

Zone 2 Detroit 60 / HD500 Triplex Split Skid HTP93

Specification

Engine TypeZone 2 Detroit S60  
Pump TypeAxon HD500, 4” OR 4 ½”  
 EnginePumpCombined
Length3912 mm2812 mm6800 mm
Width2550 mm2550 mm2550 mm
Height3124 mm3124 mm3124 mm
Gross Weight11,410 kg7,090 kg18,500 kg
Actual Weight9,960 kg6,900 kg16,900 kg
Max Flow1548 lpm  
Max Pressure772 bar  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  

View Video File (4.4 MB)

Zone 2 Detroit Inline 6-71 Diesel Driven Pump

Zone 2 Detroit 6-71 / GD230 Split Skid Triplex HTP104

Specification

Engine TypeZone 2 Detroit Inline 6-71  
Pump TypeGardner Denver GD-250, 3” Plungers  
 EnginePump 
Length3180 mm2360 mm 
Width1440 mm2300 mm 
Height2520 mm1500 mm 
Gross Weight5500 kg4000 kg 
Max Flow521 lpm  
Max Pressure429 bar  
CertificationZone 2 manned use, BS7072  
Zone 2 Diesel Driven Pump Unit Detroit 8 V92 HTP74

Zone 2 Detroit 8V92 / HD500 Triplex HTP74

Specification

Engine TypeZone 2 Detroit 8V92  
Pump TypeAxon HD500, 3 ⅜” or 4½"  
Length x Width x Height6100 x 2430 x 2860 mm  
Max Flow923 lpm  
Max Pressure1034 bar  
Weight15000 kg gross  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  
Zone 2 Diesel Driven Fluid Pump Detroit 8 V71

Zone 2 Detroit 8V71 / HD500 Triplex HTP75

Specification

Engine TypeZone 2 Detroit 8V71  
Pump TypeAxon HD500, 3 3/8 ” or 4 ½ ˮ  
Length x Width x Height6100 x 2430 x 2860 mm  
Design Weight15,000 kg gross  
Actual Weight12,000 kg  
Max Flow1560 lpm  
Max Pressure1034 bar  
CertificationATEX (Zone 2 manned use), DNV 2.7-1  
Zone 2 Electric Air Driven Containerised Pump Set

Zone 1 Electric / Hughes HPS400 / Air Hydro Annulus Test Pump HTP72

Specification

Pump TypeHughes HPS400 Triplex  
Length x Width x Height2991 x 2438 x 2438 mm  
Max Flow60 lpm  
Max Pressure828 bar  
Gross Weight10000 kg  
CertificationDNV 2.7-1, ATEX (Ex II 2 G T3) –Zone 1  
Zone 1 Electric Driven Well Service Pump Unit HTP103

Zone 1 Electric 75kW / Woma 50mm Triplex HTP103

Specification

MotorZone 1 75 kW, 3 ph, 50/60 hz  
Pump Type50mm Triplex  
Length x Width x Height3000 x 1400 x 2080 mm  
Max Flow250 lpm  
Max Pressure345 bar  
Max Gross Weight6500 kgs  
CertificationATEX, DNV 2.7-1  
Zone II Diesel 8 V92 T HD500 triplex HTP76

Zone 2 Diesel 8V92T / HD500 Triplex HTP76

Specification

Engine TypeZone 2 Detroit 8V92T  
Pump TypeAxon HD500 fitted with 4.5” plungers  
Length x Width x Height6100 x 2430 x 2860 mm  
Max Flow1500 lpm  
Max Pressure772 bar  
Max Gross Weight15,000 kgs  
CertificationDNV 2.7-1, ATEX Zone 2  
Zone II Diesel 500 hp Scania Kamat triplex HTP126

Zone 2 Diesel 500 hp Scania / Kamat Triplex HTP126

Specification

Engine TypeZone 2 Scania DSI 1478  
Pump TypeKamat K35036-350A  
Length x Width x Height6000 x 2450 x 2830 mm  
Max Flow188 lpm  
Max Pressure1000 bar  
Max Gross Weight19,500 kgs (12,000 kgs shipping weight)  
CertificationDNV 2.7-1, ATEX Zone 2  

Keep in Touch

Receive the latest news from Hiretech by subscribing to our newsletter

Sign Up

Hiretech Brochure

View the latest Hiretech company brochure.

View Brochure